ENDOMATE™ Dual 

Overview

ENDOMATE™ Dual is a two-retort endothermic gas generator built for heat treatment lines that cannot tolerate an atmosphere interruption. 

Where a single-retort generator forces a full shutdown for catalyst service or maintenance, ENDOMATE™ Dual runs one retort while the second stands by — or runs both together when the line calls for peak volume. The changeover is managed by the onboard controller, not by an operator. 

Every cycle is logged: gas composition, dew point, energy consumption, and alarm history. That record is what your CQI-9 auditor asks for, and it is available without anyone transcribing a chart.

How It Works

Air and natural gas (or propane) are metered by an electronically controlled 

proportioning system, then passed over a nickel catalyst inside a heated retort. 

The reaction produces an endothermic atmosphere of approximately 40% H₂, 20% CO, 

and 40% N₂ — the carrier gas used in carburizing, carbonitriding, and neutral 

hardening.


ENDOMATE™ Dual applies this process across two independent retorts under a single 

control system, with automatic mode selection based on demand.


Product Features:

Redundant dual-retort design — Run one retort with the second on standby, or both in parallel at peak demand. Catalyst service on one retort does not stop atmosphere supply to the line.

Unattended operation — Automatic start-up, mode switching, and shutdown sequences remove the need for a dedicated operator across shifts.

Demand-matched output — The generator adjusts production to actual furnace demand rather than running at fixed maximum, cutting both gas consumption and flare-off.

Electronic air-to-gas proportioning — Replaces mechanical ratio valves with electronic metering, holding the mixture stable as ambient conditions and supply pressure shift.

Full process traceability — Continuous logging of dew point, gas composition, energy use, and alarm events, exportable for CQI-9 and IATF 16949 documentation.

Patented atmosphere circuit —【待填:专利号 + 该设计具体解决什么问题】

Layered safety interlocks — Flame supervision, over-temperature cutoff, gas pressure monitoring, and emergency purge, interlocked across both retorts.


Technical Specifications

ParameterSpecification
Output capacity (per retort)【待填】Nm³/h
Output capacity (combined)【待填】Nm³/h
Gas composition~40% H₂ / 20% CO / 40% N₂
Dew point range【待填】°C
Dew point stability【待填】±°C
Feedstock gasNatural gas / Propane / LPG
Air-to-gas ratio controlElectronic proportioning
Operating temperature【待填】°C
Power supply【待填】V / 【待填】Hz / 【待填】phase
Installed power【待填】kW
Catalyst type【待填】
Control system【待填】(PLC 型号 / HMI 尺寸)
Communication【待填】(Modbus TCP / Profinet / OPC UA?)
Dimensions (W×D×H)【待填】mm
Weight【待填】kg
Certifications【待填】(CE / ISO 9001 / 其他)


Applications

ENDOMATE™ Dual supplies carrier atmosphere for:


- Gas carburizing and carbonitriding of automotive gears, shafts, and fasteners

- Neutral hardening in sealed quench and continuous belt furnaces  

- Bright annealing of steel wire and tube

- Multi-furnace heat treatment plants requiring uninterrupted atmosphere supply


Typical installations: 【待填:如"2–8 furnace lines"或客户规模描述】


FAQ

Q: What is the difference between a dual-retort and a single-retort endothermic generator?

A: A single-retort generator must be taken offline entirely for catalyst replacement or 

retort maintenance, which stops atmosphere supply to the furnace line. A dual-retort 

generator such as ENDOMATE™ Dual carries two independent retorts under one control 

system, allowing one to be serviced while the other continues production.


Q: How much endothermic gas does ENDOMATE™ Dual produce?

A: 【待填】Nm³/h per retort, 【待填】Nm³/h with both retorts operating in parallel.


Q: Can ENDOMATE™ Dual operate without an attendant?

A: Yes. Start-up, mode switching, and shutdown run as automatic sequences, with 

layered safety interlocks including flame supervision, over-temperature cutoff, and 

emergency purge.


Q: What feedstock gases are supported?

A: Natural gas, propane, and LPG. Air-to-gas ratio is held by electronic proportioning 

rather than mechanical ratio valves.


Q: Does ENDOMATE™ Dual support CQI-9 documentation requirements?

A: The generator logs dew point, gas composition, energy consumption, and alarm history 

continuously. These records can be exported for CQI-9 and IATF 16949 process 

documentation.


Q: Can ENDOMATE™ Dual be retrofitted to an existing furnace line?

A: Yes. 【待填:接口要求、场地要求、典型改造周期】